PTB Sales: 866-332-0500


HiTek Power MH & OL Series Power Supplies

HiTek
ModelPrice
MH100/502N/05$500
MH100/502NSB$500
MH100/XI2200014-01$500
OL400/502/31$800
OL400/502/36$800
OL400/A104/126$800
OL400/XX100009490, XX100009530, A1036430$800
OL400/XX10027010$800

HiTek
ModelPrice
OL6000/104/19$1,200
OL6000/803/10$800
OL6000 HV$2,500
OL8000/104/05$2,500
OL8000/144/08$1,200
OL8000/144/08 HV$3,500
OL8000/803/10$1,200
OL8000/803/10 HV$3,000

HiTek
ModelPrice
OL8000/A104/126$1,200
OL8000/A104/126 HV$3,500
OL8000/XX100009490, XX1000010640$1,200
OL8000/XX10023820$1,200
OL8000/XX10023820 HV$3,500
OL20K$3,500
OL20K$3,500
OL20KE/104/07$5,500

Many of these HiTek Power power supplies are either surplus new or have had little use. They are made for a high level of stability used in the ion implanter environment. They work as two units: a 19" rack mount power converter unit, and a separate OL HV unit which employs a modular disc construction that mounts within the implanter. HiTek Power was called Advance HiVolt.

OL8000Output VoltageOutput Current(Max)Output Power
OL8000/80380kV100mA8kW
OL8000/104100kV80mA8kW
OL8000/124120kV67mA8kW
OL8000/144140kV57mA8kW
OL8000/164160kV50mA8kW
OL8000/184180kV45mA8kW
OL8000/204200kV40mA8kW

They utilize high frequency MOSFET switching techniques incorporating low RDS MOSFETS switched at 50kHz. This combined with non-dissipative snubbing to achieve a high power to volume ratio, results in cooler operation and increased reliability. The OL6000 and OL400 have both been designed to function in tandem with each other, thus offering superior ripple and noise performance at output levels below 6kV. HiTek bought Advance Hivolt.

OL6000Output VoltageOutput Current(Max)Output Power
OL6000/60360kV100mA6kW
OL6000/80380kV75mA6kW
OL6000/104100kV60mA6kW
OL6000/124120kV50mA6kW
OL6000/144140kV42mA6kW
OL6000/164160kV37mA6kW
OL6000/184180kV33mA6kW
OL6000/204200kV30mA6kW

SpecificationsMH100/502OL400/602/19OL6000/803/10
Input Voltage+24V DC (~2V DC)187 to 229V AC single phaseThree phase 208V +10%, 48 to 62Hz
Input Current6A max<6A RMS<27A per phase
Input Frequency-47 to 63Hz-
Output Voltage0 to 50kV6kV/75mA0 to 80kV DC/0 to 75mA
Calibration-Calibration between voltage demand, output voltage and voltage monitor +/-0.5% or 7.5v, whichever is greater+/-0.5% or 100v, whichever is greater
Line Regulation<0.01% for a 10% change in input voltage<3V for 10% line change<16V change in output voltage for +10% change in input
Load Regulation<0.1% for 10% to full load<3V for 0 to 100% change in current<40V change in output voltage for a change in current between zero and rated current
Recovery Time-0.1 seconds to within 1% of set voltage
Ripple<0.1% peak to peak<3V peak to peak<150V peak to peak
Drift-<0.02%/hour, <0.05%/8 hours (after 1 hour warm up time)
Reliability~0.1% over an 8 hour period after 30 min. warm-upMTBF of 18,000 hours at 25°C-
Efficiency->80% at full power-
Temp. Coefficient200ppm/°C over-operating temp. range<50ppm/°C (0 to +50°C)<200ppm/°C
Operating Temp.0 to +45°C10°C to 40°C10°C to +40°C
Storage Temp.-20°C to +60°C-20°C to +85°C-20°C to +50°C
Humidity85% maximum relative humidity non-condensing95% maximum relative humidity85% maximum relative humidity

HiTek DC High Voltage Power Supply Service

We provide repair service for the following models:

Series MH100

Series OL6000

Series OL8000

Series OL10K

Series OL20K

Series OLS10K

Series OLS10KD

Call for a quote. 90 day warranty service on all HiTek Power DC high voltage power supplies.

What you need, when you need it!